Doosan
 

 

Drill Modules

 

  For more information Download the Brochure: PDF ICON

Single-Stage Rotary Screw Compressor Modules Package

• Hydraulically driven fan for oil cooler (electric fan on HP185CMH)
• Pusher fan with straight through cooling fl ow keeps package interior temperature near ambient temperature
• Heavy-gauge sheet metal housing
• Heavy-duty frame with integral fork lift tubes (VHP300CMH and larger)
• Two-stage air cleaner(s) with safety elements (single-stage on VHP300CMH)
• Includes mounting interface for SAE “D” hydraulic motor (VHP300CMH and larger)
• Flexible drive coupling with standard interface for 1.75", 13 tooth, 8-16 DP/30˚ splined shaft hydraulic motor (VHP300CMH and larger)
•Hydraulically driven compressor with hydraulic motor included in the package (HP185CMH only)
•Removable roof panel and side panels
•Mounting provisions on sides and bottom of frame (bottom only on HP185CMH)
•Includes pressure regulation, automatic blowdown systems and 80 PSIG minimum pressure valve

MODEL  HP185CMH

VHP300CMH 

VHP500CMH HP600CMH VHP600CM
Rated Capacity - cfm 185 300 500 600 600
Pressure - psi  150 200 200 150 200
RPM Imput 2800 2750 2100 2300 2200
Airend Size 85mm CF90 178.5mm 178.5mm 226mm
Airend Stage 1 1 1 1 1
Input HP Required (includes fan) 62 111 189 186 220
Comprsesor Module - lb 480 1145 1540 1540

2160

Separation Module - lb N/A 260 260 260 260
Oil - lb 22 75 75 75 75
Total (Dry) - lb 480 1405 1800 1800 2420
Total (Wet) - lb 500 1480 1875 1875 2495
Length - in 35 43.4 43.4 43.4 52.5
Width – in   23 38.4 38.4 38.4 41.9
Height – in  36.5 40 40 40 43
A/E Discharge - in N/A 2 2 2 2
Fan Drive Method 12 or 24 VDC Hydraulic Hydraulic Hydraulic Hydraulic

Hydraulic Flow Required GPM

N/A 13.2 13.2 13.2 N/A

Hydraulic Pressure Required

N/A 315 600 600 N/A
Fan RPM 2800 1750 1750 1750 N/A
*Fan HP <1 3 5 5 N/A
Hydraulic Connections (inlet & outlet) N/A -12 SAE -12 SAE -12 SAE N/A
Case Drain Provided N/A -6 SAE -6 SAE -6 SAE N/A

Two-Stage Rotary Screw Compressor Modules Package

• Choice of shaft drive (CM or CMH), direct engine coupling (CMH only) or hydraulic drive of compressor (CMH only)
• Onboard air-cooled compressor oil cooler, fan shaft driven (CM) or optional hydraulic drive (CMH)
• Pusher fan with straight through cooling fl ow keeps package interior temperature near ambient
• Heavy-gauge sheet metal housing
• Heavy-duty frame with integral fork lift tubes
• Dual two-stage air cleaners with safety elements
• Available hydraulic drive adapter plate for mounting motor (CMH only)
• Flexible drive coupling included with hydraulic drive adapter plate
• Removable roof panel (CMH only) and side- or rear-access panels
• Mounting provisions on sides and bottom of frame
• Includes pressure regulation, separator scavenge and automatic blowdown systems, 165 PSIG min. pressure valve
• Air filters protected inside the package from rain and damage
• Roof-mounted automatic shutters protect oil cooler from environment and debris (CM only)
• Integral lifting hard points at top corners of housing

MODEL  XHP750CM

XHP750CMH

XHP900CM XHP900CMH
Rated Capacity - cfm 750 750 900 900
Pressure - psi  350 350 350 350
RPM Imput 1850/2100 1850/2100 1800/2100 1800/2100
Airend Size HR2 HR2 HR2 HR2
Airend Stage 2 2 2 2
Input HP Required (includes fan) 330/336 324 395/401 390
Comprsesor Module - lb 3100 3100 3100 3100
Separation Module - lb 815 815 815 815
Oil - lb 407 407 407 407
Total (Dry) - lb 3915 3915 3915 3915
Total (Wet) - lb 4322 4322 4322 4322
Length - in 63.6 56 63.6 56
Width – in   51.6 51 51.6 51
Height – in  59.2 55.4 59.2 55.4
A/E Discharge - in 3 3 3 3
Fan Drive Method Airend Shaft Hydraulic Airend Shaft Hydraulic

Hydraulic Flow Required GPM

N/A 12.6 N/A 12.6

Hydraulic Pressure Required

N/A 920 N/A 920
Fan RPM 1850/2100 1300 1850/2100 1300
*Fan HP 13/19 7* 12/18 7*
Hydraulic Connections (inlet & outlet) N/A -12 SAE N/A -12 SAE
Case Drain Provided N/A -6 SAE N/A -6 SAE

MODEL  XHP1070CM

XHP1070CMH

XHP1250CM XHP1250CMH
Rated Capacity - cfm 1070 1070 1250 1250
Pressure - psi  350 350 350 350
RPM Imput 1800/2100 1800/2100 1800/2100 1800/2100
Airend Size HR2.5 HR2.5 HR2.5 HR2.5
Airend Stage 2 2 2 2
Input HP Required (includes fan) 437/440 437/434 496/517 502/512
Comprsesor Module - lb 3400 3400 3400 3400
Separation Module - lb 815 815 815 815
Oil - lb 407 407 407 407
Total (Dry) - lb 4215 4215 4215 4215
Total (Wet) - lb 4622 4622 4622 4622
Length - in 63.6 56 63.6 56
Width – in   51.6 51 51.6 51
Height – in  59.2 55.4 59.2 55.4
A/E Discharge - in 3 3 3 3
Fan Drive Method Airend Shaft Hydraulic Airend Shaft Hydraulic

Hydraulic Flow Required GPM

N/A 15.5 N/A 19.4

Hydraulic Pressure Required

N/A 1400 N/A 2200
Fan RPM 1800/2100 1600 1800/2100 2000
*Fan HP 13/19 13 19/30 25*
Hydraulic Connections (inlet & outlet) N/A -12 SAE N/A -12 SAE
Case Drain Provided N/A -6SAE N/A -6 SAE

*Theoretical hydraulic power required at fan motor. Fan motor total efficiency factored in.